Insurance and Electrical Safety: What Loss Adjusters Look For (and How to Avoid Repudiation Risk)

PAT Testing 13a Plug

If an electrical fault causes fire, shock, or business interruption, your insurer’s loss adjuster will ask one question first: was it reasonably preventable? The quickest way to answer “yes” is with solid, up‑to‑date evidence of compliance and maintenance. This guide explains what adjusters typically review, the gaps that trigger higher scrutiny or repudiation, and how to build an audit‑ready evidence bundle.

Note: This article is general guidance, not legal advice. Always follow your policy wording and your insurer’s instructions.

Key takeaways

  • Loss adjusters look for causation, compliance, and control: what happened, were systems maintained to prevent danger, and did you act on known issues?
  • The fastest way to de‑risk a claim is a clear evidence trail: EICR, PAT, remedial close‑outs, and safety logbooks.
  • Biggest pitfalls: unresolved C1/C2/FI from EICRs, no PAT schedule in higher‑risk areas, missing RCD and emergency lighting checks, weak contractor controls.
  • Prepare now: align your testing calendar, close actions promptly, and keep documentation tidy and accessible.

What loss adjusters check first

AreaWhat they look forWhy it matters
CausationOrigin and cause report, witness statements, photos/CCTVConfirms whether the event was accidental, foreseeable or due to neglect
Compliance baselineLatest EICR; prior EICRs; closure of C1/C2/FI itemsShows fixed wiring was inspected and defects were resolved
Appliance regimePAT records, asset register, failed item quarantine processDemonstrates portable equipment was maintained to prevent danger
Fire safety systemsFire alarm weekly tests and 6‑monthly services (BS 5839‑1), emergency lighting monthly/annual tests (BS 5266‑1)Addresses detection/evacuation performance and duty of care
Protection devicesRCD/RCBO presence and push‑button test logs; evidence of correct specification and operationMitigates shock/fire risk and nuisance tripping issues
High‑risk areasKitchens, workshops, construction areas: shorter PAT intervals, cable management, heater/charging policiesHigher exposure requires stronger controls and evidence
Contractor controlCompetence checks, RAMS, permits to work, isolation recordsPrevents contractor‑caused faults; supports subrogation if needed
Documentation qualityDates, signatures, serial numbers, photos, clear defect descriptionsStrong evidence accelerates settlement and reduces disputes

Your evidence bundle: what “good” looks like

Document / recordWhat good looks likeCommon gaps
EICR (BS 7671)Current EICR; previous versions; written proof that C1/C2/FI were rectified with dates and signaturesOpen C2/FI items; no proof of remedials; missing schedules
PAT certificates & asset registerRisk‑based intervals by area; pass/fail list; quarantined items with repair/replace notes; photos for fails“Annual by default,” no risk rationale; no asset IDs; lost fail evidence
Fire alarm logbookWeekly call‑point tests recorded, 6‑monthly services, fault logsMissed weeks; no service sheets; unresolved faults
Emergency lighting recordsMonthly functional tests; annual 3‑hour duration test with remedialsSkipped annual test; no retest after repairs
RCD/RCBO checksPush‑button test logs as per labels; periodic verification in EICRNo evidence of user tests; non‑functional devices left in service
Contractor controlsCompetence/insurance checks, RAMS, permits to work, isolation/lockout recordsNo permits; informal work; unclear responsibilities
Policies & trainingPortable heater policy, lithium‑ion charging policy, user visual check guidance, incident reporting procedureAd‑hoc rules; no staff briefings; near misses not recorded
Photos & diagramsBefore/after remedials, labelled boards, circuit schedules, cable managementNo visual evidence; unlabeled DBs; messy leads/blocks

Common reasons electrical claims are repudiated or reduced

Repudiation triggerExampleHow to prevent
Known defects not fixedEICR lists C2 “no RCD protection” on socket circuits; months later a shock incident occursClose C1/C2/FI promptly; keep written completion evidence
No evidence of maintenanceNo PAT in kitchens/workshops; damaged lead causes fireAdopt risk‑based PAT with documented intervals and fail quarantine
Misuse/overloadingDaisy‑chained multiway adaptors under desks; heater + kettle on one blockStaff training, extension block policy, load management checks
Bypassed protectionRCDs replaced with non‑RCD devices; labels ignoredSpecify correct protective devices; log and test RCDs routinely
Uncontrolled contractorsUnlicensed contractor modifies a DB; arcing leads to failureVetting, RAMS, permits, isolation records; post‑works verification
Inadequate fire safety upkeepEmergency lighting fails on evacuation; greater lossMonthly/annual tests with remedials; keep logbook evidence
Non‑compliant equipmentUnapproved chargers/e‑bike batteries ignite while chargingProcurement controls; lithium battery policy; designated charging areas

Reduce repudiation risk: practical steps

  • Build a risk‑based compliance calendar and stick to it. See our deadlines guide: https://allinonepropat.co.uk/compliance/uk-electrical-compliance-deadlines-facilities-managers-guide/
  • Close EICR C1/C2/FI items quickly and file completion evidence.
  • Run targeted PAT schedules: shorter intervals for kitchens, workshops, and construction equipment; longer for low‑risk IT. Book PAT: https://allinonepropat.co.uk/pat-testing/
  • Keep logbooks current: fire alarm weekly tests, emergency lighting monthly/annual, RCD push‑button tests.
  • Control high‑risk behaviours: portable heaters, multiway adaptors, lithium battery charging.
  • Vet and control contractors: competence, RAMS, permits, lock‑out/tag‑out, post‑work checks.
  • Maintain clear asset IDs, photos and serial numbers for high‑value kit.
  • Retain records in one place and back them up; make “the evidence bundle” easy to retrieve fast.

After an incident: your 72‑hour plan

TimeframeActionsEvidence to capture
Hour 0–8Make safe, isolate, first aid; notify insurer/broker per policy; preserve scenePhotos/video, witness names, equipment IDs, isolation records
Hour 8–24Commission an origin‑and‑cause report; secure damaged equipmentEngineer notes, failure point images, device specifications
Day 2–3Compile evidence bundle and submit: EICR, PAT, logbooks, remedial certificates, RAMS/permits if contractors involvedSingle indexed pack (PDF/portal); name files clearly

How long to keep records

Record typeTypical retentionNotes
EICR and remedialsAt least current + previous cycle (commonly 5-10 years)Keep longer for high‑risk/insured asset requirements
PAT recordsAs long as the device remains in serviceRetain fail logs and repair evidence
Fire alarm and emergency lighting logbooks5+ yearsLocal authority/insurer may specify longer
RCD checks and DB labellingAs long as device remains in serviceUpdate when devices are replaced
Contractor RAMS/permits6–10 yearsAlign with limitation periods and insurer guidance

How All In One Pro PAT Testing supports your insurance evidence

  • Risk‑based PAT schedules aligned to the environment and usage
  • Clear pass/fail reports, asset registers, and the fail quarantine process
  • Photo evidence of significant defects and corrective actions
  • Coordination with your EICR provider to help close actions quickly
  • Out‑of‑hours, phased testing to minimise disruption

Learn more or request a quote: https://allinonepropat.co.uk/pat-testing/

FAQs: Insurance, loss adjusters and electrical safety

Do insurers require annual PAT testing?

No fixed interval is mandated across the board. Insurers expect a risk‑based regime aligned to the environment and equipment. High‑risk areas need shorter intervals; low‑risk office IT can be longer. Keep records to evidence your rationale.

Will a missing EICR automatically void insurance?

Not automatically, but a lack of an in‑date EICR and unresolved C1/C2/FI defects will increase scrutiny and can lead to reduced or repudiated claims if the loss relates to wiring issues.

What documents should I send to a loss adjuster after an electrical fire?

Provide EICR (current and previous), remedial certificates, PAT records and asset list, fire alarm and emergency lighting logbooks, RCD test logs, contractor RAMS/permits (if relevant), photos of the scene/equipment, and incident reports.

Does PAT replace an EICR?

No. EICR covers fixed wiring; PAT covers portable equipment. Both sets of records are often required to evidence prevention and maintenance.

Are portable heaters an insurance red flag?

Yes. Heaters drive many seasonal incidents. Have a heater policy, avoid daisy‑chaining, test regularly, and consider safer alternatives.

What about lithium‑ion batteries (e‑bikes, scooters, tools)?

Set a charging policy: approved chargers only, no overnight unattended charging, designated areas, and regular visual checks. Record incidents/near misses.

How can I prove contractor competence if works caused a fault?

Keep contractor vetting records (qualifications, insurance), RAMS, permits to work, isolation/lock‑out records, and post‑works test results.

+ + + + + + + + +

Make your evidence “insurer‑ready.” Align PAT with your compliance calendar, close EICR actions fast, and keep logbooks tight.

+ + + + + + + + +

References for further reading

Core legal and HSE guidance

British Standards and IET references

Insurance and loss adjusting

Fire safety and battery risks

+ + + + + + + + +